Record and Review Temperature Conditions Throughout Storage and Transport
The Elitech RC-4 temperature data logger provides continuous temperature recording for cold chain logistics, refrigerators, freezers, storage facilities, laboratories and other temperature-sensitive environments. Its reusable design combines an internal temperature sensor with support for an external wired probe, allowing the logger to adapt to different monitoring applications.
Up to 16,000 temperature readings can be stored in the logger’s internal memory. Recorded data can then be transferred to a computer through the USB interface and reviewed using ElitechLog software, where users can analyse temperature trends, configure logger parameters and export reports for documentation.
Internal Sensor for Ambient Temperature Monitoring
The built-in temperature sensor can be used to monitor ambient conditions inside storage areas, transport containers, laboratories and other controlled environments. The internal sensor provides a measuring range from -30°C to +60°C.
External Probe for Refrigerators and Freezers
For applications requiring the sensor to be positioned separately from the logger, the RC-4 supports an external wired temperature probe. The external probe extends the measuring range to -40°C to +85°C, making it particularly useful for refrigerators, freezers, cold storage units and temperature-controlled cabinets.
Internal or External Temperature Measurement
The RC-4 can operate using either its internal sensor or the connected external probe, depending on the monitoring configuration. The logger records from one temperature sensor at a time rather than recording both internal and external temperatures simultaneously.
Store Up to 16,000 Temperature Readings
Internal memory provides capacity for up to 16,000 temperature records, allowing temperature conditions to be documented over extended monitoring periods without requiring continuous connection to a computer.
Configurable Recording Interval
The logging interval can be configured to suit different monitoring requirements. Short intervals provide more detailed temperature histories, while longer intervals can be used for extended monitoring applications.
Configurable High and Low Temperature Alarms
Upper and lower temperature limits can be configured using the software. Alarm indications help users identify whether recorded conditions have moved outside the required temperature range during the monitoring period.
USB Data Transfer with ElitechLog
Recorded temperature data can be transferred to a Windows or macOS computer through the USB interface. The RC-4 is supported by ElitechLog, allowing users to configure logger parameters, review recorded measurements and display temperature data graphically.
Export Temperature Reports for Documentation
ElitechLog allows recorded RC-4 data to be exported in formats including PDF, XLS and TXT. This makes temperature records easier to archive, analyse or share as part of routine cold chain and storage documentation.
Reusable Temperature Monitoring
Unlike single-use shipment loggers, the RC-4 is designed for repeated monitoring applications. This makes it a practical option for refrigerators, freezers, laboratories, warehouses and other locations where temperature recording is required on an ongoing basis.
Key Features
- Reusable temperature data logger
- Built-in internal temperature sensor
- Support for external wired temperature probe
- -30°C to +60°C internal sensor range
- -40°C to +85°C external probe range
- 16,000-record memory capacity
- 0.1°C temperature resolution
- Configurable high and low temperature alarms
- Adjustable logging interval
- USB connection for computer data transfer
- Compatible with ElitechLog software
- PDF, XLS and TXT data export through ElitechLog
- Replaceable battery
- Suitable for repeated monitoring applications
Technical Specifications
| Model | Elitech RC-4 |
|---|---|
| Product Type | Reusable temperature data logger |
| Internal Sensor Range | -30°C to +60°C |
| External Probe Range | -40°C to +85°C |
| Temperature Accuracy | ±0.5°C (-20°C to +40°C); ±1.0°C outside this range |
| Resolution | 0.1°C |
| Memory Capacity | 16,000 temperature records |
| Logging Interval | Configurable from 10 seconds to 24 hours |
| Sensor Selection | Internal sensor or external probe |
| Interface | USB |
| Software | ElitechLog – Windows and macOS |
| Data Export | PDF / XLS / TXT via ElitechLog |
| Alarm Settings | Configurable high and low temperature limits |
| Power Supply | Replaceable CR2450 battery |
| Dimensions | 84 × 44 × 20mm |
Typical Applications
- Cold chain monitoring
- Refrigerators and freezers
- Pharmaceutical storage
- Food storage
- Laboratories
- Cold rooms
- Warehouses and storage facilities
- Temperature-controlled transport
- Routine temperature documentation
Explore our complete range of temperature data loggers for cold chain, storage, transport and laboratory monitoring.